555 123 45 67 info@yourdomain.com
09:00-18:00
Frequently Asked Questions

FAQ

For EX9000 Series

AIO Sampling rate list:  

  

 Sampling  Accuracy  Zero Drift  Span Drift
 9011  10Hz  ±0.05%  ±0.5μV/  ±25ppm/
 9011P  10Hz  ±0.05%  ±0.5μV/  ±25ppm/
 9012F  10Hz  ±0.25%  ±20μV/  ±25ppm/
 9012D  10Hz  ±0.05%  ±20μV/  ±25ppm/
 9013D  10Hz  ±0.05%  ±0.5μV/  ±1.0ppm/
 9014D  10Hz  ±0.05%  ±20μV/  ±20μV/
 9015  12Hz  ±0.05%  ±0.5μV/  ±25ppm/
 9016D  10Hz  ±0.05%  ±0.5μV/  ±25ppm/
 9016PD  10Hz  ±0.05%  ±0.5μV/  ±25ppm/
 9017  10Hz  ±0.1%  ±20μV/  ±25ppm/
 9017F  75Hz  ±0.5%  ±20μV/  ±25ppm/
 9018  10Hz  ±0.1%  ±0.5μV/  ±25ppm/
 9018P  10Hz  ±0.1%  ±0.5μV/  ±25ppm/
 9033D  15Hz  ±0.1%  ±0.5μV/  ±1.0ppm/

Please don’t calibrate before you really understand. Detailed see the EX9000 user manual.

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

For EX9188XD Series

1  UNDER HYPERTERMINAL OF  PC.

2  POWER OFF THE EX-9188

3  PUT EX-9188END  INT* PIN TO TOUCH ( CONNECT) GND.

4  POWER ON THE EX-9188 THEN RELEASE ( DISCONNECT) THE INIT * PIN TO GND.

5  UNDER HYPERTERMINAL TO THE IMAGE FILE :

TRNASFER —— SEND FILE——–PROTOCOL ( X MODEM) ———FILE NAME

——OK ( WITHIN 60 SEC) ( REFER User Manual, P10,P24,25,26,27).

6  THE SCREEN WULL SHOW CCCCCC. ……( WHEN TRANSFER FINISHED , EX-9188 WILL REBOOT AGAIN).

The INIT* pin must be disconnected right after executing uploading process.

Make sure click “transfer” at menu bar and choose the right function and file within 60sec after typing “xm /s” or “xm /r”. The transfer protocol must be “Xmodem”.

Open the cover and check the jumper5, 6 and 7. If pin 1 and 2 are connected, COM1 is RS232. If pin 2 and 3 are connected, it’s RS485.

For EX9188XD Series

1  UNDER HYPERTERMINAL OF  PC.

2  POWER OFF THE EX-9188

3  PUT EX-9188END  INT* PIN TO TOUCH ( CONNECT) GND.

4  POWER ON THE EX-9188 THEN RELEASE ( DISCONNECT) THE INIT * PIN TO GND.

5  UNDER HYPERTERMINAL TO THE IMAGE FILE :

TRNASFER —— SEND FILE——–PROTOCOL ( X MODEM) ———FILE NAME

——OK ( WITHIN 60 SEC) ( REFER User Manual, P10,P24,25,26,27).

6  THE SCREEN WULL SHOW CCCCCC. ……( WHEN TRANSFER FINISHED , EX-9188 WILL REBOOT AGAIN).

The INIT* pin must be disconnected right after executing uploading process.

Make sure click “transfer” at menu bar and choose the right function and file within 60sec after typing “xm /s” or “xm /r”. The transfer protocol must be “Xmodem”.

Open the cover and check the jumper5, 6 and 7. If pin 1 and 2 are connected, COM1 is RS232. If pin 2 and 3 are connected, it’s RS485.